| Product
Test where field configuration is important |
PC-based
data acquisition and test systems |
Remote,
distributed data acquisition with software
configuration |
Industrial
process control systems |
| Field Input: Signal Types &
Ranges |
mV, V, mA,
RTD, TC, Frequency, rms, DC & AC strain gage, LVDT,
RVDT, Torque |
mV, V, mA,
Loop Powered mA, Potentiometer, Slidewire, Frequency,
RTD, TC, DC strain gage |
mV, V, mA,
RTD, TC, Lo-and Hi-level Digital Inputs |
mV, V, mA,
Loop Powered mA, RTD, TC |
| System Interface: Signal Types
& Ranges |
Dual
outputs: voltage (-10 to +10 V or 0 to +10 V) and
current (0 to 20 mA or 4 to 20 mA) |
Voltage
(-5 to +5 V or 0 to +5 V) |
Communications (RS-232C or RS-485
multi-drop) |
Voltage (0
to +10 V or +1 to +5 V) |
| Field Output Signal Types &
Ranges |
Current (0
to 20 mA or 4 to 20 mA) |
Current (0
to 20 mA or 4 to 20 mA) |
Current (0
to 20 mA or 4 to 20 mA) and Lo-and Hi-level Digital
Outputs |
Voltage
(-10 to +10 V) or current (0 to 20 mA or 4 to 20
mA) |
| Signal Bandwidth |
Narrow (3
Hz) and wide (10 kHz) |
Narrow (4,
10, 100,400 Hz) and wide (10 kHz) |
Narrow (4
Hz). A/D runs at 9 samples/sec |
Narrow (3,
100, 300, 400 Hz) |
| Power Supply
Requirements |
±15 V and
+24 V DC (AC and DC input power supplies available) |
+5 V DC
(AC power supplies available) |
+5 V DC
(AC power supplies available) |
+24 V
DC |
| Isolation: Channel to Channel
and Field to System |
1500 V
Peak |
1500 V
rms |
Two
versions: 1500 V rms and 2500 V rms |
1500 V
rms |
| Input/Output Range
Configuration |
Over 100
standard ranges plus infinite user-configurations and
factory custom ranges |
Over 75
standard ranges plus infinite factory custom ranges |
Four 6B
models handle over 35 input/output ranges, configured
via software |
Over 140
standard ranges. Special ranges available for OEM
quantities |
| Backplane Options |
4-, 8- and
16-channel, rack-mountable backplanes |
8- and
16-channel, rack-mountable backplanes in both
multiplexed and non-multiplexed configurations. 1- and
2-channel, DIN-rail mountable cards |
1-, 4- and
16-channel, rack mountable backplanes in both RS-232C
and RS-485 versions |
4-, 8- and
16-channel, rack mountable backplanes. Single-channel
DIN-rail sockets |
| Operating temperature
range |
-25° C to
+85° C |
-25° C to
+85° C |
-25° C to
+85° C |
-40° C to
+85° C |
| Other features |
User
calibration potentiometers. Plug-in ranging card allows
field configuration. |
Built-in
multiplexing circuit for handling large point count
systems. Laser-trimmed, never needs calibration. |
16-bit,
high accuracy A/D converter. Engineering units
conversion. 24-channel digital I/O panel with SSR
interface. |
Small